title: How to size and select control valves and actuators based on flow?
description: Sizing Control Valves
---

[Skip to content](https://knowledge.yorkland.net/knowledge/how-to-size-and-select-control-valves-and-actuators-based-on-flow#main-content)

English

Show submenu for translations

[Submit Support Ticket](https://knowledge.yorkland.net/knowledge/kb-tickets/new?hsLang=en)

![yorkland-bcs-stacked.jpg\]](https://knowledge.yorkland.net/hs-fs/hubfs/yorkland-bcs-stacked.jpg?height=40&name=yorkland-bcs-stacked.jpg)

Open main navigation

Close main navigation

- English
  
  Show submenu for translations
- [Submit Support Ticket](https://knowledge.yorkland.net/knowledge/kb-tickets/new)
- Go to yorkland.net

 Go to yorkland.net

 How can we help you?

- There are no suggestions because the search field is empty.

1. [Help Center](https://knowledge.yorkland.net/knowledge?hsLang=en)
2. [HVACR Components](https://knowledge.yorkland.net/knowledge/hvacr-components?hsLang=en)

# How to size and select control valves and actuators based on flow?

## Sizing Control Valves

Valve sizes are usually determined by the CV (Valve co-efficient) CV is determined by the pressure drop(difference between the inlet and outlet pressure) and the flow (GPM) general. Good control is achieved by assuming a 3 to 5 lb pressure drop. For example a flow of 28 gpm will have a CV, based on these assumptions,Â ofÂ CV- 13 to 16. The valve would be between 1 1/4 to 1 1/2 in valve size. If the system is sized right , control valves would be usually .5 in less than the pipe size.

We carry various valve manufacturers such as Belimo, Johnson Controls, Honeywell and Siemens. Most actuators that drive the valves are available in 0-10vdc or o to 20ma. This control signal is usually determined by the temperature control you select.

[Yorkland Controls](https://www.yorkland.net/)has the experience to size valves correctly for you.

 

- [Helpful Articles](https://knowledge.yorkland.net/knowledge/helpful-articles?hsLang=en)
- [Building Automation](https://knowledge.yorkland.net/knowledge/building-automation?hsLang=en#main-content)

    - [Field Controllers](https://knowledge.yorkland.net/knowledge/building-automation?hsLang=en#field-controllers)
    - [Supervisory Systems](https://knowledge.yorkland.net/knowledge/building-automation?hsLang=en#supervisory-systems)
- [Combustion](https://knowledge.yorkland.net/knowledge/combustion?hsLang=en)
- [HVACR Components](https://knowledge.yorkland.net/knowledge/hvacr-components?hsLang=en)
- [Supplier Support Sites](https://knowledge.yorkland.net/knowledge/supplier-support-sites?hsLang=en)
- [Yorkland Partner Portal](https://knowledge.yorkland.net/knowledge/yorkland-partner-portal?hsLang=en)
- [Support Ticket Form Link](https://knowledge.yorkland.net/knowledge/support-ticket-form-link?hsLang=en#main-content)

    - [Support Ticket](https://knowledge.yorkland.net/knowledge/support-ticket-form-link?hsLang=en#support-ticket)

[![Chill listening crop-3](https://knowledge.yorkland.net/hs-fs/hubfs/YKL%20Logo-1.png?width=38&height=27&name=YKL%20Logo-1.png "Chill listening crop-3")](https://www.yorkland.net/)

yorkland.net

Copyright © 2026, Yorkland Controls + Building Controls Solutions